Normal
0
7.8 磅
0
2
false
false
false
EN-US
ZH-CN
X-NONE
/* Style Definitions */
table.MsoNormalTable
{mso-style-name:æ™®é€šè¡¨æ ¼;
mso-tstyle-rowband-size:0;
mso-tstyle-colband-size:0;
mso-style-noshow:yes;
mso-style-priority:99;
mso-style-parent:””;
mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
mso-para-margin:0cm;
mso-pagination:widow-orphan;
font-size:10.0pt;
font-family:”Times New Roman”,serif;}
Introduction:
1.Technical specifications:
1.1 Dimensions:
25mm×25mm×240mm
1.2
Net weight: 280g
1.3
Power source
1.3.1
Power supply: rechargeable Lithium battery
1.3.2
Battery mode: ICR 18490
1.3.3
Battery voltage and capacity: 3.7V/ 1400mAh,Battery has protection against Over-voltage,
over-current and short circuit.
1.3.4
Adapter Power Input: 100V to 240V, 50Hz/60 Hz Input Power: 10VA Power Output:
DC5V/1A
1.4
Light source:
1.4.1
5W high power blue light LED
1.4.2
Checking method: the LED light is fine when the light is on during operating
correctly.
1.4.3
The wave length of this product can match with the clinical dental resin
solidification, such as 3M, Dentsply etc.
1.4.4
Wave length: 440nm-480nm
1.5 Light intensity:
P1 mode
1200-1800mW/cm2
P2 mode 1200mW/cm2~1600mW/cm2
P3 mode 1200mW/cm2~1600mW/cm2
2. Operation:
2.1
Press the mode button. Following two modes are available.
2.1.1
TURBO Mode: screen shows P1, Press the time button to select of time which
could be 1 and 3 seconds.Its output light intensity is about 1800mW/cm2
2.1.2
NORMAL Mode: screen shows P2, Press the time button to select of time which
could be 5,10 ,15and 20 seconds.Its output light intensity is about 1600 mW/cm2
2.2
During the operation, put the disposable sleeve on the top of the main unit,
aim the top at the correct position, press the ON/OFF button and the main unit
will produce “Bi” sound, the curing light radiates blue light and
starts working according to the set modes. Meanwhile, it starts counting down
and will produce tone at every 5 seconds, it stops working when counting down
to “0”.
2.3
During operation, the blue light can be stopped by press the power button at
any time.
2.4
After a working cycle, operator can press the ON/OFF switch to start another
working cycle. Stop operating if the equipment began to heat obviously, do not
restart until the equipment cool down. Suggest continues working cycle less
than 10 times.
2.5
Low power detective circuit is fixed inside of the main unit, when low power is
detected, the display screen of main unit will wink, please charge in time.
2.6
When the battery needs to be charged, connect the plug of the adapter into the
AC100V~240V power supply. Then connect the output plug of the adapter to the DC
5.0V input plug of the pedestal, and then the logo turn to blue. Put the main
unit to the charging point of the pedestal, the display screen turn to
scrolling display, and the curing lights starts charging.
2.7
After operating, take off the disposable sleeve and throw away, forbidden to
reuse.
2.8 This
equipment will turn off automatically if don’t any action within 2 minutes,
turn it on by press any button.
2.9
The depth of solidification of composite is no less than 2mm per 1 second.
Â
Material:
The handle
is made of plastic,The
lamp holder is made of metal